- 41 -
Display Name, Function, Setting Range Factory Default Value
Display selection CH1 input value/A1 value (SE2 A)
Input value /A1 value (SE1 A)
IN
OUT
• Selects items to be indicated on the displays.
• Selection item:
SE2 A:
: CH1 input value /A1 value
: CH2 input value /A1 value
: Input value (CH1/CH2)
: No indication (Only the Power indicator is lit.)
SE1 A:
: Input value /A1 value
: Input value
: A1 value
: No indication (Only the Power indicator is lit.)
Indication time 00.00 (Continuous indication)
IN
OUT
• Sets the indication time of the displays after final key operation.
Not available if [No indication (Only the Power indicator is lit.)]
is selected in [Display selection].
Displays will go off (Only the Power indicator is lit.) after the indication
time has elapsed.
When the , , or SUB-MODE key is pressed, or when power
is turned ON again, the displays will light again.
• Setting Range:
00.00: Continuous indication
00.01 (1 second) to 60.00 (60 minutes) (Minutes.Seconds)